Haifeng Machinery

Hyundai DP086CDP vs Perkins 1506AE88TAG4

Compare Hyundai DP086CDP and Perkins 1506AE88TAG4 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 7.527 L and 8.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationHyundai DP086CDPPerkins 1506AE88TAG4
Standby electrical (50 Hz)247 kWe246 kWe
Prime electrical (50 Hz)224 kWe226 kWe
Standby electrical (60 Hz)278 kWe277 kWe
Prime electrical (60 Hz)251 kWe252 kWe
Other recorded mechanical power (duty unspecified)Not listed301 kW
Displacement7.527 L8.8 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,500 RPMNot listed
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationU.S. EPA Final Tier 4Unregulated
Dry weight939 kgNot listed
OriginSouth KoreaUnited States

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Hyundai DP086CDP: Review the model record and available supporting documents

Perkins 1506AE88TAG4: Review the model record and available supporting documents

Choosing between Hyundai DP086CDP and Perkins 1506AE88TAG4

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.