Haifeng Machinery

Hyundai DP126CB vs VMAN D15A2

Compare Hyundai DP126CB and VMAN D15A2 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 11.1 L and 14.618 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationHyundai DP126CBVMAN D15A2
Standby electrical (50 Hz)326 kWe327 kWe
Prime electrical (50 Hz)295 kWe297 kWe
Standby electrical (60 Hz)356 kWeNot listed
Prime electrical (60 Hz)321 kWeNot listed
Displacement11.1 L14.618 L
ConfigurationL6V8
Cylinders68
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedUnregulated
Dry weightNot listedNot listed
OriginSouth KoreaChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Hyundai DP126CB: Review the model record and available supporting documents

VMAN D15A2: Review the model record and available supporting documents

Choosing between Hyundai DP126CB and VMAN D15A2

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.