Haifeng Machinery

Jenbacher J420 vs Jichai L16V190ZLT

Compare Jenbacher J420 and Jichai L16V190ZLT by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 61.1 L and 115.7 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationJenbacher J420Jichai L16V190ZLT
Standby electrical (50 Hz)Not listedNot listed
Prime electrical (50 Hz)1,562 kWe1,600 kWe
Standby electrical (60 Hz)Not listedNot listed
Prime electrical (60 Hz)1,427 kWeNot listed
Other recorded mechanical power (duty unspecified)1,562 kW1,600 kW
Displacement61.1 L115.7 L
ConfigurationV20V16
Cylinders2016
Recorded engine speed1,500 RPM1,000 RPM
FuelNatural GasNatural Gas
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedUnregulated
Dry weightNot listedNot listed
OriginAustriaChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Jenbacher J420: Review the model record and available supporting documents

Jichai L16V190ZLT: Review the model record and available supporting documents

Choosing between Jenbacher J420 and Jichai L16V190ZLT

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.