Compare Kirloskar 6R1080TA and Volvo Penta TAD750GE by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 6.5 L and 7.15 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Kirloskar 6R1080TA | Volvo Penta TAD750GE |
|---|---|---|
| Standby electrical (50 Hz) | 114.8 kWe | 115 kWe |
| Prime electrical (50 Hz) | 94.6 kWe | 105 kWe |
| Standby electrical (60 Hz) | 124.2 kWe | 134 kWe |
| Prime electrical (60 Hz) | 112.8 kWe | 117 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 146 kW |
| Displacement | 6.5 L | 7.15 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Tier 2 | EU Stage IIIA / EPA Tier 3 |
| Dry weight | Not listed | Not listed |
| Origin | India | Sweden |
Kirloskar 6R1080TA: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Kirloskar 6R1080TA: Review the model record and available supporting documents
Volvo Penta TAD750GE: Review the model record and available supporting documents
Choosing between Kirloskar 6R1080TA and Volvo Penta TAD750GE
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.