MAN E 2876 LE302 vs PSI 10L T
Compare MAN E 2876 LE302 and PSI 10L T by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 12.8 L and 9.73 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | MAN E 2876 LE302 | PSI 10L T |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 200 kWe |
| Prime electrical (50 Hz) | 202 kWe | 180 kWe |
| Standby electrical (60 Hz) | Not listed | 204 kWe |
| Prime electrical (60 Hz) | 202 kWe | 170 kWe |
| Other recorded mechanical power (duty unspecified) | 210 kW | 200 kW |
| Displacement | 12.8 L | 9.73 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,800 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Stationary |
| Dry weight | Not listed | 1,180 kg |
| Origin | Germany | United States |
MAN E 2876 LE302: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
MAN E 2876 LE302: Review the model record and available supporting documents
PSI 10L T: Review the model record and available supporting documents
Choosing between MAN E 2876 LE302 and PSI 10L T
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.