Mitsubishi GS12R-PTK vs Waukesha VHP F3524GSI
Compare Mitsubishi GS12R-PTK and Waukesha VHP F3524GSI by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 49.03 L and 57.7 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Mitsubishi GS12R-PTK | Waukesha VHP F3524GSI |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | 700 kWe | Not listed |
| Standby electrical (60 Hz) | 750 kWe | Not listed |
| Prime electrical (60 Hz) | Not listed | 680 kWe |
| Other recorded mechanical power (duty unspecified) | 700 kW | 708 kW |
| Displacement | 49.03 L | 57.7 L |
| Configuration | V12 | L6 |
| Cylinders | 12 | 6 |
| Recorded engine speed | 1,500 RPM | 1,200 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Stationary | Unregulated |
| Dry weight | 5,350 kg | Not listed |
| Origin | Japan | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Mitsubishi GS12R-PTK: Review the model record and available supporting documents
Waukesha VHP F3524GSI: Review the model record and available supporting documents
Choosing between Mitsubishi GS12R-PTK and Waukesha VHP F3524GSI
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.