Guascor G-48FL vs Waukesha VHP F3524GSI
Compare Guascor G-48FL and Waukesha VHP F3524GSI by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 47.9 L and 57.7 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Guascor G-48FL | Waukesha VHP F3524GSI |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | 703 kWe | Not listed |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | 761 kWe | 680 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 708 kW |
| Displacement | 47.9 L | 57.7 L |
| Configuration | V16 | L6 |
| Cylinders | 16 | 6 |
| Recorded engine speed | 1,500 RPM | 1,200 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | Spain | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Guascor G-48FL: Review the model record and available supporting documents
Waukesha VHP F3524GSI: Review the model record and available supporting documents
Choosing between Guascor G-48FL and Waukesha VHP F3524GSI
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.