Haifeng Machinery

Mitsubishi S6R2-PTA vs SDEC 6JTAA17-G310

The Mitsubishi S6R2-PTA and SDEC 6JTAA17-G310 are both diesel generator engines in a similar power class. Both are rated at roughly 732 kVA. Displacement is 29.96 L versus 17 L. The table below compares their full specifications side by side.

SpecificationMitsubishi S6R2-PTASDEC 6JTAA17-G310
Headline rating737 kVA726 kVA
Standby (50 Hz)589.5 kWe581 kWe
Prime (50 Hz)535.5 kWe527 kWe
Standby (60 Hz)481.5 kWe—
Prime (60 Hz)436.5 kWe—
Displacement29.96 L17 L
ConfigurationL6L6
Cylinders66
Rated speed1,500 / 1,800 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
EmissionsUnregulatedChina National Stage III / Unregulated
Dry weight——
OriginJapanChina

Choosing between Mitsubishi S6R2-PTA and SDEC 6JTAA17-G310

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing. The Mitsubishi S6R2-PTA has the higher headline kVA rating in this pair, but site conditions and duty cycle can still change the final recommendation.