Compare Mitsubishi S6R2-PTAA and Perkins 4006-23TAG2A by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 29.96 L and 23 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationMitsubishi S6R2-PTAAPerkins 4006-23TAG2A
Standby electrical (50 Hz)657 kWe656 kWe
Prime electrical (50 Hz)598.5 kWe597 kWe
Standby electrical (60 Hz)535.5 kWe660 kWe
Prime electrical (60 Hz)486 kWe600 kWe
Displacement29.96 L23 L
ConfigurationL6V6
Cylinders66
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedUnregulated
Dry weightNot listedNot listed
OriginJapanUnited Kingdom

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Mitsubishi S6R2-PTAA: Review the model record and available supporting documents

Perkins 4006-23TAG2A: Review the model record and available supporting documents

Choosing between Mitsubishi S6R2-PTAA and Perkins 4006-23TAG2A

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.