Haifeng Machinery

Volvo Penta TAD1384VE vs Weichai WP12D353E200

Compare Volvo Penta TAD1384VE and Weichai WP12D353E200 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 12.8 L and 12 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationVolvo Penta TAD1384VEWeichai WP12D353E200
Standby electrical (50 Hz)Not listed318 kWe
Prime electrical (50 Hz)Not listed259 kWe
Standby electrical (60 Hz)319 kWeNot listed
Prime electrical (60 Hz)290 kWeNot listed
Other recorded mechanical power (duty unspecified)343 kWNot listed
Displacement12.8 L12 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,800 RPM1,500 RPM
FuelDiesel/HVODiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationU.S. EPA Final Tier 4China National Stage II / Unregulated
Dry weightNot listedNot listed
OriginSwedenChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Volvo Penta TAD1384VE: Review the model record and available supporting documents

Weichai WP12D353E200: Review the model record and available supporting documents

Choosing between Volvo Penta TAD1384VE and Weichai WP12D353E200

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.