FPT C90 TE2
FPT C90 TE2 10.3L 6-cylinder diesel engine for generator sets. 300 ekW standby at 60Hz / 250 ekW standby at 50Hz. U.S. EPA Tier 3. Turbocharged Aftercooled.
Cursor 9

- Configuration
- L6
- Displacement
- 10.3 L
- Fuel
- Diesel
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| Rating | Prime | Standby |
|---|---|---|
| Mechanical power kWm | 250 | 277.8 |
| Electrical output kWe | 225 | 250 |
| Apparent power kVA | 281.3 | 312.5 |
60 Hz1800 RPM
| Rating | Prime | Standby |
|---|---|---|
| Mechanical power kWm | 300 | 333.3 |
| Electrical output kWe | 270 | 300 |
| Apparent power kVA | 337.5 | 375 |
Datasheet & documents
Match the model number on your engine plate to the document. Check its revision date and the speed and duty listed for each power rating.
Technical specifications
Technical Specifications
| Brand | FPT |
| Model | C90 TE2 |
| Series | Cursor 9 |
| Configuration | L6 |
| Cylinders | 6 |
| Displacement | 10.3 L |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | U.S. EPA Tier 3 |
| Country of Origin | Italy |
Check your engine model
The FPT C90 TE2 is a diesel generator-drive engine for 50 Hz and 60 Hz generator sets, rated at 313 kVA / 250 kWe / standby rating. Match the model and serial number on your engine plate when requesting a manual or parts. The ratings and emissions information below help identify the version fitted to your generator.
Other ways this model is written
C90 TE2 repair parts
Haifeng supplies overhaul parts, filters, fuel injection parts and engine controls. Send your engine plate and the parts you need for a parts and delivery quote.
Get a parts & air-shipping quoteWorldwide air shipping. Tell us your city and country for a shipping quote and estimated arrival date.
Find the right part
Send your engine plate, part numbers or photos, quantity, and delivery city. Parts can differ between versions of the same engine.
Get my parts quote on WhatsAppWe’ll confirm the correct parts, stock and delivery cost before you order.
Opens WhatsApp. Attach photos in the chat.
Photos and details to send
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Parts reference availability
We do not have a reviewed public parts preview for this model yet. Send the engine details and tell us what needs repair.
Get help with this engine
Need a manual, a replacement part or help with an engine problem? Tell us what happened and include the serial number if you have it.
Other ways to contact us
Scan QRHide QR
General WhatsApp chatScan with your phone. Add the model and your request in chat.Haifeng sales teamNeed help after checking the documents?
Send us the part number or describe the problem. This engine model is included in your message.
Send this model enquiry by emailOr browse Haifeng's diesel generator sets
Frequently asked questions
What is the power output of the FPT C90 TE2?
The FPT C90 TE2 is rated at 313 kVA standby / 281 kVA prime at 50 Hz (1,500 rpm); and 375 kVA standby / 338 kVA prime at 60 Hz (1,800 rpm).
Does the C90 TE2 run at 50 Hz or 60 Hz?
The FPT C90 TE2 is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the FPT C90 TE2 use?
The FPT C90 TE2 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the C90 TE2?
The FPT C90 TE2 is an inline-6 (6-cylinder) engine with a displacement of 10.3 L.
What emissions information is listed for the C90 TE2?
This record lists U.S. EPA Tier 3 for the FPT C90 TE2. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the FPT C90 TE2?
The FPT C90 TE2 is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the C90 TE2?
This page links reference documents for the FPT C90 TE2. Check each document's title, model coverage, revision and rating conditions before using it for selection.