FPT
FPT F36ETVP03.A85
FPT F36ETVP03.A85 4-cylinder diesel engine for generator sets. 88.2 kWm prime / 97.6 kWm standby at 60Hz. EPA Tier 4 Final (DOC+DPF+SCR). Turbocharged, Intercooled.
Overhaul & repair parts- Manufacturer files
- 2 datasheets
- Last updated
- 2026-06-11
- Package route
- diesel generator sets
- Standby Power · 60 Hz
- 110 kVA
- Electrical Output
- 88 kWe
- Cylinders
- L4
- Displacement
- 3.6 L
- Rated Speed
- 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf · kWe estimated — see note below
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 88.2 | 79.4 | 99.3 |
| Standby Power | 97.6 | 87.8 | 109.7 |
Note: The manufacturer does not publish a separate kWe rating for this engine. kWe values shown are estimated from the rated mechanical output (kWm) using a conservative 90% alternator efficiency factor.
Ask about FPT F36ETVP03.A85
Choose parts / service or sourcing. Your message includes this model and page link.
FPT F36ETVP03.A85 overhaul & repair parts
Already running a FPT F36ETVP03.A85? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
These categories have model-related records. Part numbers need further checking before we display them here.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with F36ETVP03.A85 and your selected categories included. Attach your photos there.
FPT F36ETVP03.A85 generator set context
The FPT F36ETVP03.A85 is listed here as a diesel generator-drive engine for 60 Hz generator sets, with a headline 110 kVA / 88 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | FPT |
| Model | F36ETVP03.A85 |
| Configuration | L4 |
| Cylinders | 4 |
| Displacement | 3.6 L |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | U.S. EPA Final Tier 4 |
| Country of Origin | Italy |
Frequently asked questions
What is the power output of the FPT F36ETVP03.A85?
The FPT F36ETVP03.A85 is rated at 110 kVA standby / 99 kVA prime at 60 Hz (1,800 rpm).
Does the F36ETVP03.A85 run at 50 Hz or 60 Hz?
The FPT F36ETVP03.A85 is rated for 60 Hz (1,800 rpm).
What fuel does the FPT F36ETVP03.A85 use?
The FPT F36ETVP03.A85 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the F36ETVP03.A85?
The FPT F36ETVP03.A85 is an inline-4 (4-cylinder) engine with a displacement of 3.6 L.
What emissions information is listed for the F36ETVP03.A85?
This record lists U.S. EPA Final Tier 4 for the FPT F36ETVP03.A85. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the FPT F36ETVP03.A85?
The FPT F36ETVP03.A85 is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the F36ETVP03.A85?
This page links reference documents for the FPT F36ETVP03.A85. Check each document's title, model coverage, revision and rating conditions before using it for selection.