FPT
FPT N67TEVP06.00
FPT N67TEVP06.00 6-cylinder 6.7L diesel engine for generator sets. 151 kWm prime / 167 kWm standby at 60Hz. EPA Tier 4 Final (DOC+DPF+SCR). Turbocharged, Intercooled.
Overhaul & repair parts- Manufacturer files
- 2 datasheets
- Last updated
- 2026-06-11
- Package route
- diesel generator sets
- Standby Power · 60 Hz
- 188 kVA
- Electrical Output
- 150 kWe
- Cylinders
- L6
- Displacement
- 6.7 L
- Rated Speed
- 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf · kWe estimated — see note below
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 151 | 135.9 | 169.9 |
| Standby Power | 167 | 150.3 | 187.9 |
Note: The manufacturer does not publish a separate kWe rating for this engine. kWe values shown are estimated from the rated mechanical output (kWm) using a conservative 90% alternator efficiency factor.
Ask about FPT N67TEVP06.00
Choose parts / service or sourcing. Your message includes this model and page link.
FPT N67TEVP06.00 overhaul & repair parts
Already running a FPT N67TEVP06.00? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
These categories have model-related records. Part numbers need further checking before we display them here.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with N67TEVP06.00 and your selected categories included. Attach your photos there.
FPT N67TEVP06.00 generator set context
The FPT N67TEVP06.00 is listed here as a diesel generator-drive engine for 60 Hz generator sets, with a headline 188 kVA / 150 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | FPT |
| Model | N67TEVP06.00 |
| Configuration | L6 |
| Cylinders | 6 |
| Displacement | 6.7 L |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | U.S. EPA Final Tier 4 |
| Country of Origin | Italy |
Frequently asked questions
What is the power output of the FPT N67TEVP06.00?
The FPT N67TEVP06.00 is rated at 188 kVA standby / 170 kVA prime at 60 Hz (1,800 rpm).
Does the N67TEVP06.00 run at 50 Hz or 60 Hz?
The FPT N67TEVP06.00 is rated for 60 Hz (1,800 rpm).
What fuel does the FPT N67TEVP06.00 use?
The FPT N67TEVP06.00 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the N67TEVP06.00?
The FPT N67TEVP06.00 is an inline-6 (6-cylinder) engine with a displacement of 6.7 L.
What emissions information is listed for the N67TEVP06.00?
This record lists U.S. EPA Final Tier 4 for the FPT N67TEVP06.00. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the FPT N67TEVP06.00?
The FPT N67TEVP06.00 is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the N67TEVP06.00?
This page links reference documents for the FPT N67TEVP06.00. Check each document's title, model coverage, revision and rating conditions before using it for selection.