Generac
Generac RG03824
Protector QS
Generac RG03824 is a 38 kWe, 60 Hz emergency-standby generator using a turbocharged and aftercooled 2.4 L inline-four gaseous engine at 1800 RPM. EPA annual certification data records the matching natural-gas and propane engine families at 38.6 kW maximum engine test power.
Overhaul & repair parts- Manufacturer files
- 2 datasheets
- Last updated
- 2026-07-26
- Package route
- gas generator sets
- Standby Power · 60 Hz
- 48 kVA
- Electrical Output
- 38 kWe
- Cylinders
- L4
- Displacement
- 2.4 L
- Rated Speed
- 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Standby Power | 38.6 | 38 | 47.5 |
Ask about Generac RG03824
Choose parts / service or sourcing. Your message includes this model and page link.
Generac RG03824 overhaul & repair parts
Already running a Generac RG03824? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
Start with engine identification
We do not have a reviewed public parts preview for this model yet. Send the engine details and tell us what needs repair.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with RG03824 and your selected categories included. Attach your photos there.
Generac RG03824 generator set context
The Generac RG03824 is listed here as a natural gas generator-drive engine for 60 Hz generator sets, with a headline 48 kVA / 38 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Generac |
| Model | RG03824 |
| Series | Protector QS |
| Configuration | Inline-4 Turbocharged Aftercooled |
| Cylinders | 4 |
| Displacement | 2.4 L |
| Compression Ratio | 9.5:1 |
| Fuel Type | Natural Gas |
| Ignition Type | Spark Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | U.S. EPA Stationary |
| Certifications | U.S. EPA Stationary, U.S. EPA Stationary Emergency |
| Country of Origin | United States |
Frequently asked questions
What is the power output of the Generac RG03824?
The Generac RG03824 is rated at 48 kVA standby at 60 Hz (1,800 rpm).
Does the RG03824 run at 50 Hz or 60 Hz?
The Generac RG03824 is rated for 60 Hz (1,800 rpm).
What fuel does the Generac RG03824 use?
The Generac RG03824 is a Natural Gas generator-set engine.
What is the displacement and cylinder configuration of the RG03824?
The Generac RG03824 is an inline-4 (4-cylinder) engine with a displacement of 2.4 L.
What emissions information is listed for the RG03824?
This record lists U.S. EPA Stationary for the Generac RG03824. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the Generac RG03824?
The Generac RG03824 is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the RG03824?
This page links reference documents for the Generac RG03824. Check each document's title, model coverage, revision and rating conditions before using it for selection.