Source notes
Official Power HF 495/4100/4102 operation manual, August 2013, printed page 17; source: powerhf.com · PDF.
Generator application D suffix.
Twelve-hour mechanical rating 30.1 kW at 1500 rpm.
Separately published one-hour mechanical rating 33 kW at 1500 rpm.
These are legacy duty definitions, not verified ISO prime/standby or electrical ratings.
Four-stroke, naturally aspirated, water-cooled inline four; electrical starting; firing order 1-3-4-2.
Weight is manufacturer net weight.
FLAG: K4100D table prints 95 mm bore and 3.26 L, inconsistent with 4100 family designation; displacement and bore withheld pending clarification.
Production status unknown; discontinued is the user-authorized catalogue classification, not manufacturer-confirmed withdrawal.
Family manual includes this exact base model; do not transfer specifications to suffixed variants.