Lister Petter
Lister Petter LP443G4
Mechanical Pump
Lister Petter LP443G4 mechanical pump diesel generator-drive engine. 50 Hz 80 kWe prime / 88 kWe standby; 60 Hz 90 kWe prime / 100 kWe standby. Euro Stage II emissions. Dual-frequency switchable.
Chat on WhatsApp about this engine
Opens WhatsApp with Lister Petter LP443G4 and this page link filled in.
- Manufacturer files
- 2 datasheets
- Last updated
- 2026-07-24
- Package route
- diesel generator sets
- Standby Power · 50 Hz
- 110 kVA
- Electrical Output
- 88 kWe
- Cylinders
- L4
- Displacement
- 4.3 L
- Rated Speed
- 1,500 / 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 90 | 80 | 100 |
| Standby Power | 100 | 88 | 110 |
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 100 | 90 | 112.5 |
| Standby Power | 111 | 100 | 125 |
Lister Petter LP443G4 generator set context
The Lister Petter LP443G4 is listed here as a diesel generator-drive engine for 50 Hz and 60 Hz generator sets, with a headline 110 kVA / 88 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Lister Petter |
| Model | LP443G4 |
| Series | Mechanical Pump |
| Configuration | L4 |
| Cylinders | 4 |
| Displacement | 4.3 L |
| Compression Ratio | 16:1 |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Euro Stage II |
| Country of Origin | United Kingdom |
Frequently asked questions
What is the power output of the Lister Petter LP443G4?
The Lister Petter LP443G4 is rated at 110 kVA standby / 100 kVA prime at 50 Hz (1,500 rpm); and 125 kVA standby / 113 kVA prime at 60 Hz (1,800 rpm).
Does the LP443G4 run at 50 Hz or 60 Hz?
The Lister Petter LP443G4 is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the Lister Petter LP443G4 use?
The Lister Petter LP443G4 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the LP443G4?
The Lister Petter LP443G4 is an inline-4 (4-cylinder) engine with a displacement of 4.3 L.
What emissions standard does the LP443G4 meet?
The Lister Petter LP443G4 is certified to Euro Stage II emissions standards.
Is the Lister Petter LP443G4 still in production?
Yes — the Lister Petter LP443G4 is a current production model.
Is a datasheet available for the LP443G4?
Yes — an official Lister Petter datasheet for the Lister Petter LP443G4 can be downloaded from this page.