Haifeng Machinery
Perkins logo

Perkins

Perkins 1104C44TG2

1104 Series

In Production

Perkins 1104C44TG2 generator-drive diesel engine discovered in the GenProBase public selector. GenProBase lists 2 row(s) across 50Hz, 60Hz with 4.4 L displacement, 4L cylinders, liquid-cooled cooling, and EU Stage II emissions labeling. Treat this row as source-discovered and prioritize OEM datasheet attachment in a follow-up pass.

Chat on WhatsApp about this engine

Opens WhatsApp with Perkins 1104C44TG2 and this page link filled in.

Chat on WhatsApp
Manufacturer files
No datasheet
Last updated
2026-08-05
Package route
diesel generator sets
Standby Power · 50 Hz
66 kVA
Electrical Output
53 kWe
Cylinders
L4
Displacement
4.4 L
Rated Speed
1,500 / 1,800 RPM

Power Ratings

kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf

50 Hz1500 RPM

kWmkWekVA
Prime Power5448
Standby Power5953

60 Hz1800 RPM

kWmkWekVA
Prime Power6054
Standby Power6760
Shareable spec cardPerkins 1104C44TG2 summary imageOpen image
Perkins 1104C44TG2 4.4L L4, turbocharged diesel generator engine — 66 kVA standby specifications

Perkins 1104C44TG2 generator set context

The Perkins 1104C44TG2 is listed here as a diesel generator-drive engine for 50 Hz and 60 Hz generator sets, with a headline 66 kVA / 53 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.

Also searched as

1104c44tg2Perkins 1104C44TG21104 Series 1104C44TG2

Technical Specifications

BrandPerkins
Model1104C44TG2
Series1104 Series
ConfigurationL4, turbocharged
Cylinders4
Displacement4.4 L
Fuel TypeDiesel
Ignition TypeCompression Ignition
Cooling MethodLiquid-Cooled
Emissions StandardEU Stage II
CertificationsEU Stage II
Country of OriginUnited Kingdom / Brazil

Frequently asked questions

What is the power output of the Perkins 1104C44TG2?

The Perkins 1104C44TG2 is rated at 66 kVA standby / 60 kVA prime at 50 Hz (1,500 rpm); and 75 kVA standby / 68 kVA prime at 60 Hz (1,800 rpm).

Does the 1104C44TG2 run at 50 Hz or 60 Hz?

The Perkins 1104C44TG2 is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).

What fuel does the Perkins 1104C44TG2 use?

The Perkins 1104C44TG2 is a diesel generator-set engine.

What is the displacement and cylinder configuration of the 1104C44TG2?

The Perkins 1104C44TG2 is an inline-4 (4-cylinder) engine with a displacement of 4.4 L.

What emissions standard does the 1104C44TG2 meet?

The Perkins 1104C44TG2 is certified to EU Stage II emissions standards.

Is the Perkins 1104C44TG2 still in production?

Yes — the Perkins 1104C44TG2 is a current production model.