Volvo Penta
Volvo Penta TAD532GE
D5 Power Generation
Volvo Penta TAD532GE discontinued legacy industrial engine. Volvo Penta lists TAD532GE in the D5 power-generation product archive, and the legacy bulletin/rating tables support the 4.76 L inline-four generator-drive identity. Model identity and legacy status were cross-validated against Volvo Penta industrial archive pages, Volvo Group launch material, and Volvo Penta dealer rating sheets.
Chat on WhatsApp about this engine
Opens WhatsApp with Volvo Penta TAD532GE and this page link filled in.
- Manufacturer files
- 1 datasheet
- Last updated
- 2026-08-11
- Package route
- diesel generator sets
- Standby Power · 50 Hz
- 142 kVA
- Electrical Output
- 114 kWe
- Cylinders
- L4
- Displacement
- 4.76 L
- Rated Speed
- 1,500 / 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 112 | 104 | 130 |
| Standby Power | 125 | 114 | 142 |
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 115 | 106 | 132 |
| Standby Power | 129 | 117 | 146 |
Volvo Penta TAD532GE generator set context
The Volvo Penta TAD532GE is listed here as a diesel generator-drive engine for 50 Hz and 60 Hz generator sets, with a headline 142 kVA / 114 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Volvo Penta |
| Model | TAD532GE |
| Series | D5 Power Generation |
| Configuration | L4, turbocharged air-to-air charge-cooled diesel genset engine |
| Cylinders | 4 |
| Displacement | 4.76 L |
| Compression Ratio | 18:1 |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | EU Stage II / TA-luft |
| Certifications | EU Stage II, TA-luft |
| Country of Origin | Sweden |
| Year Introduced | 2005 |
| Year Discontinued | 2023 |
Frequently asked questions
What is the power output of the Volvo Penta TAD532GE?
The Volvo Penta TAD532GE is rated at 142 kVA standby / 130 kVA prime at 50 Hz (1,500 rpm); and 146 kVA standby / 132 kVA prime at 60 Hz (1,800 rpm).
Does the TAD532GE run at 50 Hz or 60 Hz?
The Volvo Penta TAD532GE is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the Volvo Penta TAD532GE use?
The Volvo Penta TAD532GE is a diesel generator-set engine.
What is the displacement and cylinder configuration of the TAD532GE?
The Volvo Penta TAD532GE is an inline-4 (4-cylinder) engine with a displacement of 4.76 L.
What emissions standard does the TAD532GE meet?
The Volvo Penta TAD532GE is certified to EU Stage II / TA-luft emissions standards.
Is the TAD532GE still in production?
No — the Volvo Penta TAD532GE is discontinued (production ended around 2023). Its specifications and datasheets remain archived here for reference.
Is a datasheet available for the TAD532GE?
Yes — an official Volvo Penta datasheet for the Volvo Penta TAD532GE can be downloaded from this page.