Volvo Penta
Volvo Penta TWD1653GE
16 Litre Series
Volvo Penta TWD1653GE - Turbocharged water-to-air intercooled 16 litre diesel engine for generator sets. 604 kWm standby at 50Hz.
Overhaul & repair parts- Supporting documents
- 1 document · 1 datasheet
- Last updated
- 2026-06-29
- Package route
- diesel generator sets
- Standby Power · 50 Hz
- 718 kVA
- Electrical Output
- 574 kWe
- Cylinders
- L6
- Displacement
- 16.1 L
- Rated Speed
- 1,500 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 577.8 | 520 | 650 |
| Standby Power | 637.8 | 574 | 717.5 |
Ask about Volvo Penta TWD1653GE
Choose parts / service or sourcing. Your message includes this model and page link.
Volvo Penta TWD1653GE overhaul & repair parts
Already running a Volvo Penta TWD1653GE? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
These categories have model-related records. Part numbers need further checking before we display them here.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with TWD1653GE and your selected categories included. Attach your photos there.
Volvo Penta TWD1653GE generator set context
The Volvo Penta TWD1653GE is listed here as a diesel generator-drive engine for 50 Hz generator sets, with a headline 718 kVA / 574 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Volvo Penta |
| Model | TWD1653GE |
| Series | 16 Litre Series |
| Configuration | L6 |
| Cylinders | 6 |
| Displacement | 16.1 L |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Euro Stage IIIA / U.S. EPA Tier 3 |
| Country of Origin | Sweden |
Frequently asked questions
What is the power output of the Volvo Penta TWD1653GE?
The Volvo Penta TWD1653GE is rated at 718 kVA standby / 650 kVA prime at 50 Hz (1,500 rpm).
Does the TWD1653GE run at 50 Hz or 60 Hz?
The Volvo Penta TWD1653GE is rated for 50 Hz (1,500 rpm).
What fuel does the Volvo Penta TWD1653GE use?
The Volvo Penta TWD1653GE is a diesel generator-set engine.
What is the displacement and cylinder configuration of the TWD1653GE?
The Volvo Penta TWD1653GE is an inline-6 (6-cylinder) engine with a displacement of 16.1 L.
What emissions information is listed for the TWD1653GE?
This record lists Euro Stage IIIA / U.S. EPA Tier 3 for the Volvo Penta TWD1653GE. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the Volvo Penta TWD1653GE?
The Volvo Penta TWD1653GE is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the TWD1653GE?
This page links reference documents for the Volvo Penta TWD1653GE. Check each document's title, model coverage, revision and rating conditions before using it for selection.