Compare Cummins QST30G1 and Liebherr D976 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 30 L and 18 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins QST30G1 | Liebherr D976 |
|---|---|---|
| Standby electrical (50 Hz) | 626 kWe | 624 kWe |
| Prime electrical (50 Hz) | 582 kWe | 556.8 kWe |
| Standby electrical (60 Hz) | 751 kWe | Not listed |
| Prime electrical (60 Hz) | 700 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 847 kW | 850 kW |
| Displacement | 30 L | 18 L |
| Configuration | V12 | L6 |
| Cylinders | 12 | 6 |
| Recorded engine speed | Not listed | 1,800 RPM |
| Fuel | Diesel | Diesel/HVO |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Euro Stage V / U.S. EPA Tier 2 |
| Dry weight | Not listed | Not listed |
| Origin | United States | Switzerland |
Liebherr D976: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins QST30G1: Review the model record and available supporting documents
Liebherr D976: Review the model record and available supporting documents
Choosing between Cummins QST30G1 and Liebherr D976
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.