Haifeng Machinery

Deutz F4L2011 vs Hyundai DP023CAV

Compare Deutz F4L2011 and Hyundai DP023CAV by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 3.1 L and 1.794 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationDeutz F4L2011Hyundai DP023CAV
Standby electrical (50 Hz)26 kWe26 kWe
Prime electrical (50 Hz)23.4 kWe24 kWe
Standby electrical (60 Hz)29.9 kWe36 kWe
Prime electrical (60 Hz)26.9 kWe32 kWe
Displacement3.1 L1.794 L
ConfigurationL4L3
Cylinders43
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingOil-CooledLiquid-Cooled
Recorded emissions classificationEuro Stage IIIAEuro Stage V
Dry weightNot listedNot listed
OriginGermanySouth Korea

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Deutz F4L2011: Review the model record and available supporting documents

Hyundai DP023CAV: Review the model record and available supporting documents

Choosing between Deutz F4L2011 and Hyundai DP023CAV

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.