Hyundai DP372CC vs Mitsubishi S12R-A2PTAW
Compare Hyundai DP372CC and Mitsubishi S12R-A2PTAW by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 36.9 L and 49.03 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Hyundai DP372CC | Mitsubishi S12R-A2PTAW |
|---|---|---|
| Standby electrical (50 Hz) | 1,146 kWe | 1,164 kWe |
| Prime electrical (50 Hz) | 1,040 kWe | 1,058.4 kWe |
| Standby electrical (60 Hz) | 1,300 kWe | Not listed |
| Prime electrical (60 Hz) | 1,178 kWe | Not listed |
| Displacement | 36.9 L | 49.03 L |
| Configuration | L12 | V12 |
| Cylinders | 12 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Tier 2 |
| Dry weight | Not listed | 5,270 kg |
| Origin | South Korea | Japan |
Mitsubishi S12R-A2PTAW: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Hyundai DP372CC: Review the model record and available supporting documents
Mitsubishi S12R-A2PTAW: Review the model record and available supporting documents
Choosing between Hyundai DP372CC and Mitsubishi S12R-A2PTAW
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.