Lister Petter
Lister Petter LP613EG2
ECU Electronic
Lister Petter LP613EG2 ecu electronic diesel generator-drive engine. 50 Hz 360 kWe prime / 392 kWe standby. Euro Stage III emissions.
Overhaul & repair parts- Supporting documents
- 2 documents · 1 datasheet
- Last updated
- 2026-07-24
- Package route
- diesel generator sets
- Standby Power · 50 Hz
- 490 kVA
- Electrical Output
- 392 kWe
- Cylinders
- L6
- Displacement
- 12.8 L
- Rated Speed
- 1,500 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 386 | 360 | 450 |
| Standby Power | 426 | 392 | 490 |
Ask about Lister Petter LP613EG2
Choose parts / service or sourcing. Your message includes this model and page link.
Lister Petter LP613EG2 overhaul & repair parts
Already running a Lister Petter LP613EG2? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
These categories have model-related records. Part numbers need further checking before we display them here.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with LP613EG2 and your selected categories included. Attach your photos there.
Lister Petter LP613EG2 generator set context
The Lister Petter LP613EG2 is listed here as a diesel generator-drive engine for 50 Hz generator sets, with a headline 490 kVA / 392 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Lister Petter |
| Model | LP613EG2 |
| Series | ECU Electronic |
| Configuration | L6 |
| Cylinders | 6 |
| Displacement | 12.8 L |
| Compression Ratio | 17:1 |
| Fuel Type | Diesel |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Euro Stage III |
| Country of Origin | United Kingdom |
Frequently asked questions
What is the power output of the Lister Petter LP613EG2?
The Lister Petter LP613EG2 is rated at 490 kVA standby / 450 kVA prime at 50 Hz (1,500 rpm).
Does the LP613EG2 run at 50 Hz or 60 Hz?
The Lister Petter LP613EG2 is rated for 50 Hz (1,500 rpm).
What fuel does the Lister Petter LP613EG2 use?
The Lister Petter LP613EG2 is a diesel generator-set engine.
What is the displacement and cylinder configuration of the LP613EG2?
The Lister Petter LP613EG2 is an inline-6 (6-cylinder) engine with a displacement of 12.8 L.
What emissions information is listed for the LP613EG2?
This record lists Euro Stage III for the Lister Petter LP613EG2. Confirm the exact engine family, model year, configuration and applicable manufacturer certification documents before specifying it for a regulated project. A database label does not establish certification of a complete generator package.
What is the catalog status of the Lister Petter LP613EG2?
The Lister Petter LP613EG2 is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the LP613EG2?
This page links reference documents for the Lister Petter LP613EG2. Check each document's title, model coverage, revision and rating conditions before using it for selection.