Volvo Penta
Volvo Penta TAD582VE
D5 Generator Drive
Volvo Penta TAD582VE fixed-speed generator-drive diesel engine with published 50 Hz at 1,500 rpm and 60 Hz at 1,800 rpm ratings. The table separates mechanical engine output (kWm), electrical output (kWe), and generator-set apparent power (kVA). These derated generator ratings must not be substituted with the model's higher variable-speed off-road maximum-power curve.
Chat on WhatsApp about this engine
Opens WhatsApp with Volvo Penta TAD582VE and this page link filled in.
- Manufacturer files
- 1 datasheet
- Last updated
- 2026-07-24
- Package route
- diesel generator sets
- Standby Power · 50 Hz
- 147 kVA
- Electrical Output
- 118 kWe
- Cylinders
- L4
- Displacement
- 5.13 L
- Rated Speed
- 1,500 / 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 118 | 108 | 135 |
| Standby Power | 129 | 118 | 147 |
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 131 | 120 | 150 |
| Standby Power | 144 | 132 | 165 |
Volvo Penta TAD582VE generator set context
The Volvo Penta TAD582VE is listed here as a diesel/hvo generator-drive engine for 50 Hz and 60 Hz generator sets, with a headline 147 kVA / 118 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Volvo Penta |
| Model | TAD582VE |
| Series | D5 Generator Drive |
| Configuration | L4 |
| Cylinders | 4 |
| Displacement | 5.13 L |
| Fuel Type | Diesel/HVO |
| Ignition Type | Compression Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Euro Stage V / U.S. EPA Final Tier 4 |
| Country of Origin | Sweden |
Frequently asked questions
What is the power output of the Volvo Penta TAD582VE?
The Volvo Penta TAD582VE is rated at 147 kVA standby / 135 kVA prime at 50 Hz (1,500 rpm); and 165 kVA standby / 150 kVA prime at 60 Hz (1,800 rpm).
Does the TAD582VE run at 50 Hz or 60 Hz?
The Volvo Penta TAD582VE is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the Volvo Penta TAD582VE use?
The Volvo Penta TAD582VE is a diesel generator-set engine.
What is the displacement and cylinder configuration of the TAD582VE?
The Volvo Penta TAD582VE is an inline-4 (4-cylinder) engine with a displacement of 5.13 L.
What emissions standard does the TAD582VE meet?
The Volvo Penta TAD582VE is certified to Euro Stage V / U.S. EPA Final Tier 4 emissions standards.
Is the Volvo Penta TAD582VE still in production?
Yes — the Volvo Penta TAD582VE is a current production model.
Is a datasheet available for the TAD582VE?
Yes — an official Volvo Penta datasheet for the Volvo Penta TAD582VE can be downloaded from this page.