Waukesha
Waukesha VGF36GSI/GSID (L36GSI/GSID)
VGF
Waukesha VGF36GSI/GSID is the remote-radiator generator package using the 36 L L36GSI/GSID V12 natural-gas engine. INNIO publishes 600 kWb continuous engine output at 1800 RPM, with 560 kWe continuous and 620 kWe standby package ratings at 60 Hz.
Overhaul & repair parts- Manufacturer files
- 3 datasheets
- Last updated
- 2026-07-26
- Package route
- gas generator sets
- Standby Power · 60 Hz
- 775 kVA
- Electrical Output
- 620 kWe
- Cylinders
- V12
- Displacement
- 36 L
- Rated Speed
- 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 600 | 560 | 700 |
| Standby Power | — | 620 | — |
Ask about Waukesha VGF36GSI/GSID (L36GSI/GSID)
Choose parts / service or sourcing. Your message includes this model and page link.
Waukesha VGF36GSI/GSID (L36GSI/GSID) overhaul & repair parts
Already running a Waukesha VGF36GSI/GSID (L36GSI/GSID)? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
Start with engine identification
We do not have a reviewed public parts preview for this model yet. Send the engine details and tell us what needs repair.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with VGF36GSI/GSID (L36GSI/GSID) and your selected categories included. Attach your photos there.
Waukesha VGF36GSI/GSID (L36GSI/GSID) generator set context
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is listed here as a natural gas generator-drive engine for 60 Hz generator sets, with a headline 775 kVA / 620 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Waukesha |
| Model | VGF36GSI/GSID (L36GSI/GSID) |
| Series | VGF |
| Configuration | V12 Turbocharged Intercooled |
| Cylinders | 12 |
| Displacement | 36 L |
| Compression Ratio | 8.6:1 |
| Fuel Type | Natural Gas |
| Ignition Type | Spark Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Unregulated |
| Country of Origin | United States |
Frequently asked questions
What is the power output of the Waukesha VGF36GSI/GSID (L36GSI/GSID)?
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is rated at 775 kVA standby / 700 kVA prime at 60 Hz (1,800 rpm).
Does the VGF36GSI/GSID (L36GSI/GSID) run at 50 Hz or 60 Hz?
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is rated for 60 Hz (1,800 rpm).
What fuel does the Waukesha VGF36GSI/GSID (L36GSI/GSID) use?
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is a Natural Gas generator-set engine.
What is the displacement and cylinder configuration of the VGF36GSI/GSID (L36GSI/GSID)?
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is a V12 (12-cylinder) engine with a displacement of 36 L.
What is the catalog status of the Waukesha VGF36GSI/GSID (L36GSI/GSID)?
The Waukesha VGF36GSI/GSID (L36GSI/GSID) is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the VGF36GSI/GSID (L36GSI/GSID)?
This page links reference documents for the Waukesha VGF36GSI/GSID (L36GSI/GSID). Check each document's title, model coverage, revision and rating conditions before using it for selection.